Analisis Efektivitas Instalasi Pengolahan Air Limbah Di Rumah Sakit Bhayangkara Denpasar Tahun 2020

Budhi Darma, Made Dwipa and Notes, , S.KM., M.Si, Nengah and Marwati, S.Pd., ST., M.Si., Ni Made (2020) Analisis Efektivitas Instalasi Pengolahan Air Limbah Di Rumah Sakit Bhayangkara Denpasar Tahun 2020. Diploma thesis, Jurusan Kesehatan Lingkungan.

[img]
Preview
Text
BAB I.pdf

Download (38kB) | Preview
[img]
Preview
Text
Halaman Depan fix.pdf

Download (502kB) | Preview
[img] Text
BAB II.pdf
Restricted to Repository staff only

Download (133kB) | Request a copy
[img] Text
BAB III.pdf
Restricted to Repository staff only

Download (68kB) | Request a copy
[img] Text
BAB IV.pdf
Restricted to Repository staff only

Download (54kB) | Request a copy
[img] Text
BAB V.pdf
Restricted to Repository staff only

Download (151kB) | Request a copy
[img] Text
BAB VI.pdf
Restricted to Repository staff only

Download (28kB) | Request a copy
[img]
Preview
Text
Daftar Pustaka.pdf

Download (22kB) | Preview
[img] Text
Lampiran.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] Text
PERNYATAAN PERSETUJUAN PUBLIKASI KARYA ILMIAH.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy

Abstract

THE EFFECTIVENESS ANALYSIS OF WASTEWATER TREATMENT PLANTS AT BHAYANGKARA DENPASAR HOSPITAL 2020 ABSTRACT Bhayangkara Denpasar Hospital treats its wastewater at WWTP with a Rotating Biological Contractor treatment system. Across-sectional study design of laboratory research with eight liquid waste samples taken before and after treatment. The results of the study showed that the effectiveness of WWTP reduced the liquid waste temperature 0.11%, TDS 36.67%, TSS 50%, pH 5.75%, NH3N 51.44%, BOD5 79.87%, COD 90.24 % and Total Coliform 84.49%. The conclusion of the study is the parameters of temperature, TDS, TSS, pH, NH3N, BOD5, after processing meet the requirements of the quality standard but the Total Coliform parameters after processing do not meet the requirements in accordance with the quality standard value of the Governor of Bali No. 16 of 2016. The chlorination process at WWTP should pay attention to the contact time, the form of chlorine so that it is expected that the processing effluent for the Total Coliform parameter will be more effective and meet the specified NBM.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Data, Informasi, Perpustakaan
Subjects: T Technology > TD Environmental technology. Sanitary engineering