PERBEDAAN PENGGUNAAN DOSIS DISINFEKTAN DALAM PENURUNAN ANGKA KUMAN USAP LANTAI RUANG BELIBIS RSUD WANGAYA DENPASAR TAHUN 2018

KADEK AYU MELYAWATI, Amel and I Wayan Sali,S.KM.,M.Si, Sali and Dewa Ayu Agustini Posmaningsih,S.KM.,M.Kes, Posmaningsih (2018) PERBEDAAN PENGGUNAAN DOSIS DISINFEKTAN DALAM PENURUNAN ANGKA KUMAN USAP LANTAI RUANG BELIBIS RSUD WANGAYA DENPASAR TAHUN 2018. Diploma thesis, POLTEKKES DENPASAR.

[img]
Preview
Text (COVER SKRIPSI)
1. COVER.pdf

Download (14kB) | Preview
[img]
Preview
Text (HALAMAN JUDUL)
SKRIPSI ganti.pdf

Download (123kB) | Preview
[img]
Preview
Text (BAB I PENDAHULUAN)
14. BAB I.pdf

Download (178kB) | Preview
[img]
Preview
Text (BAB II TINJAUAN PUSTAKA)
15. BAB II.pdf

Download (178kB) | Preview
[img]
Preview
Text (BAB III KERANGKA KONSEP)
16. BAB III.pdf

Download (183kB) | Preview
[img] Text (BAB IV HASIL DAN PEMBAHASAN)
17. BAB IV baru.pdf
Restricted to Repository staff only

Download (216kB)
[img]
Preview
Text
18. BAB V (Autosaved).pdf

Download (259kB) | Preview
[img]
Preview
Text (BAB VI SIMPULAN DAN SARAN)
19. BAB VI.pdf

Download (86kB) | Preview
[img]
Preview
Text (DAFTAR PUSTAKA)
20. DAFTAR PUSTAKA.pdf

Download (162kB) | Preview
[img]
Preview
Text (LAMPIRAN)
21. LAMPIRAN.pdf

Download (406kB) | Preview

Abstract

THE DIFFERENCE IN USE OF DISINFECTANT DOSES IN DECREASE NUMBER OF FLOOR SWAB GERMS AT BELIBIS ROOM OF WANGAYA DENPASAR HOSPITAL 2018 ABSRACT The making use of disinfectant considered can reduce the number of germs on the floor and reduce the emerge of nosocomial infection cases. This study has a goal to know the difference in use of disinfectant doses to decrease number of floor swab germs at Belibis room of Wangaya Denpasar Hospital. Method used in this study is quasi experiment by using One Group Time Series Design. The type of sampling in this study is simple random sampling with Belibis room number 3. The doses of disinfectant used are 15ml/8 liter of solution, 20ml/8 liter of solution and 25ml/8 liter of solution. Five point-swabs were teken on one room and frequency of sampling twice with time intervals a day to achieve accurate results. Based on the results of statistical Paired Sample T test was obtained that third doses were difference decrease in the number of floor swab germs before and after give disinfectant a significant. At dose 15ml/8 liter of solution decrease of germicidal 5,176 with percentage 34,463%, dose 20ml/8 liter of solution decrease of germicidal 21,652 with percentage 63,197%, dose 25ml/8 liter of solution decrease of germicidal 8,643 with percentage 78,019%. Key words : Number of germs, disinfectant, Doses.

Item Type: Thesis (Diploma)
Subjects: T Technology > TD Environmental technology. Sanitary engineering
Divisions: Jurusan Kesehatan Lingkungan > Prodi D4
Depositing User: Kadek Ayu Melyawati
Date Deposited: 25 Jul 2018 00:57
Last Modified: 25 Jul 2018 00:57
URI: http://repository.poltekkes-denpasar.ac.id/id/eprint/155

Actions (login required)

View Item View Item