Perbedaan Kualitas Air Limbah RSUD Wangaya Kota Denpasar Di Inlet dan Outlet Tahun 2020

Putri P, Putu Dezy Kartika and Aryana, BE, SST,M.Si, I Ketut and Sudiadnyana,SKM,MPH, Dr.Drs. I Wayan (2020) Perbedaan Kualitas Air Limbah RSUD Wangaya Kota Denpasar Di Inlet dan Outlet Tahun 2020. Diploma thesis, Jurusan Kesehatan Lingkungan.

[img]
Preview
Text
SAMPUL.pdf

Download (1MB) | Preview
[img]
Preview
Text
Bab I fix.pdf

Download (298kB) | Preview
[img]
Preview
Text
BAB II fix.pdf

Download (424kB) | Preview
[img]
Preview
Text
BAB III fix.pdf

Download (402kB) | Preview
[img]
Preview
Text
BAB IV fix.pdf

Download (421kB) | Preview
[img] Text
BAB V fix.pdf
Restricted to Repository staff only

Download (635kB) | Request a copy
[img]
Preview
Text
BAB VI fix.pdf

Download (262kB) | Preview
[img] Text
lampiran.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[img] Text
persetujuan publikasi.pdf
Restricted to Repository staff only

Download (510kB) | Request a copy

Abstract

QUALITY DIFFERENCE OF WASTEWATER WANGAYA HOSPITAL DENPASAR CITY IN INLET AND OUTLET YEAR 2020 Abstract The hospital produces a variety of hazardous waste that needs attention because it is feared that it will negatively impact the environment around the hospital. This study measures the influent quality, effluent and effectiveness of WWTP in terms of Temperature, TSS, TDS, BOD, COD, NHȝ and Total Coliform parameters. Waste water samples were examined at the Bali Provincial Health Laboratory and the Bina Medika Laboratory. Laboratory results are compared with the Governor of Bali Province Regulation No. 16 of 2016 concerning Wastewater Quality Standards for businesses and / or health service facility activities. The test results showed the influent parameters for Temperature 29.7 ° C, TDS 2592 mg / l, TSS 350.5 mg / l, BOD 61.6 mg / l, COD 57 mg / l, NHȝ 26.72 mg / l and Total Coliform 2,600,000 MPN / 100 ml. While the effluent results for Temperature parameters are 28.1 ° C, TDS 274.8 mg / l, TSS 20.7 mg / l, BOD 21.5 mg / l, COD 51.7 mg / l, NHȝ 26.7 mg / l and Total Coliform 1470 MPN / 100 ml. The conclusion from this study that the treatment of Denpasar City Wangaya RUSD wastewater with a Biofilter system there are differences in the quality of wastewater at the inlet and outlet as well as the WWTP has been effective in reducing parameters in accordance with the required quality standards of waste. Suggestions to the IPSRS Section of Wangaya Hospital to routinely monitor WWTPs. Keywords: Inlet, Outlet and Effectiveness

Item Type: Thesis (Diploma)
Additional Information: Limbah Rumah Sakit
Uncontrolled Keywords: Air Limbah
Subjects: Q Science > QH Natural history > QH301 Biology
R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
Divisions: Jurusan Kesehatan Lingkungan > Prodi D4
Depositing User: mrs DEZY KARTIKA PUTRI P PUTU
Date Deposited: 25 Jun 2020 02:54
Last Modified: 25 Jun 2020 02:54
URI: http://repository.poltekkes-denpasar.ac.id/id/eprint/4311

Actions (login required)

View Item View Item