Perbedaan Hasil Laju Endap Darah (LED) Menggunakkan Cara Manual Tegak dan Dimiringkan

Dewi Sarihati, I Gusti Agung (2013) Perbedaan Hasil Laju Endap Darah (LED) Menggunakkan Cara Manual Tegak dan Dimiringkan. Meditory: The Journal of Medical Laboratory, 1 (1). pp. 26-32. ISSN 2338-1159

[img]
Preview
Text (Artikel LED)
LED manual tegak med jun2013.pdf

Download (4MB) | Preview

Abstract

Abstract Background hematological examination is one of the laboratory examination that can be used as a support or enforcement-related diagnosis therapy and prognosis. One of the hematologic examination is erythrocyte sedimentation rate. Erythrocyte sedimentation rate by Westergren method using the manual upright for an hour is standard procedure examination by ICSH. In its development, erythrocyte sedimentation rate test is modified by tilting shelf pipette in position 45º for 7 minutes. Objective the aims of study is determine the difference about the results erythrocyte sedimentation rate between using rack manually pipette upright and tilted shelves. Methods the type research is quasi-experimental was conducted in February-June 2012 at the Laboratory Department of Health Analyst Polytechnic of Health Denpasar. The population of research were of Health Analyst Polytechnic of Health Denpasar, as the sample is taken by 20%, that is 23 people using proportional random sampling technique. Data retrieval is done by taking a blood vein in each, and than measured value of erythrocyte sedimentation rate blood using each method were done by twice Westergren manual method upright and tilted. Results showed that the erythrocyte sedimentation rate using the method upright manual ranged 7-61 mm / h, while the results of erythrocyte sedimentation rate using the manual tilted ranges between 3-51 mm / h. The results of two independent samples T test with 95% confidence level showed no difference in the results of erythrocyte sedimentation rate using a pipette rack upright and tilted manually. Conclusion the erythrocyte sedimentation rate faster, the manual tilted Westergren method can be used in the laboratory, but the result is compared with the standard procedure ICSH that the manual upright. Keywords : LED, manual method upright and tilted

Item Type: Article
Subjects: Z Bibliography. Library Science. Information Resources > Z719 Libraries (General)
Divisions: Jurusan Analis Kesehatan
Depositing User: mrs Dewi Sarihati I G A
Date Deposited: 25 Mar 2019 02:46
Last Modified: 25 Mar 2019 02:46
URI: http://repository.poltekkes-denpasar.ac.id/id/eprint/1605

Actions (login required)

View Item View Item